Mitsubishi — 5.10.2 Relative Single-speed Motion

Chapter 5 Applied Instructions Timing diagram: The second motion follows the first motion. The second motion can not interrupt the first motion. First Execute1 Busy1 Done1 Second Test Execute2 Busy2 Done2 Error2 Motion Velocity Position  After the first single-speed motion is complete, the second single-speed motion will be executed. When the motion control function block named FIRST is executed, the first axis moves for 10,000 pulses. After the execution of the motion control function block named FIRST is complete, the motion control function block named SECOND will be executed. When the motion control function block named SECOND is executed, the first axis moves for 15,000 pulses.

 The second single-speed motion is executed before the execution of the first single-speed motion is complete. When Error2 is set to True, the first axis moves for 10,000 pulses. The motion control function block named SECOND is invalid. 5. Modules which are supported The motion control function block T_RelSeg1 supports AH05PM-5A, AH15PM-5A, AH10PM-5A, and AH20MC-5A. 5-145