Chapter 5 Applied Instructions 5-151 Input pin Name Function Data Setting value Time when a value is valid type Distance2 Relative distance for which the second motion moves DWORD K-2,147,483,646~ K2,147,483,646 (If the value of the Distance1 input pin is a positive value, the value of the Distance2 input pin must be a positive value. If the value of the Distance1 input pin is a negative value, the value of the Distance2 input pin must be a negative value.) The value of the Distance2 input pin is valid when there is a transition in the Execute input pin’s signal from low to high.
Velocity2 Target speed of the second motion DWORD K1~K2,147,483,647 The value of the Velocity2 input pin is valid when there is a transition in the Execute input pin’s signal from low to high. Output pin Name Function Data type Time when there is Time when there is a transition in an output pin’s signal from high to low a transition in an output pin’s signal from low to high Done The execution of the motion control function block is complete. BOOL There is a transition in the Done output pin’s signal when motion is complete. There is a transition in the Done output pin’s signal from high to low when there is a transition in the Execute input pin’s signal from high to low.
If the Execute input pin is set to False when motion is complete, the Done output pin will be set to False in the next cycle.