Chapter 5 Applied Instructions 4. Example Purpose: The motion control function block T_AbsSeg2 is used to start relative two-speed motion of an axis. The first motion is set so that the first axis moves at a speed of 2,000 pulses per second, and moves for 10,000 pulses. The second motion is set so that the first axis moves at a speed of 3,000 pulses per second, and moves for 15,000 pulses. Execute 1 0 t Busy 0 1 t Done 1 0 Motion 3000 t Velocity 2000 0 t Position 25000 10000 After the motion control function block is started, the first axis moves for 10,000 pulses at a speed of 2,000 pulses per second, and moves for 15,000 pulses at a speed of 3,000 pulses per second. 5.
Modules which are supported 0 t The motion control function block T_RelSeg2 supports AH05PM-5A, AH15PM-5A, AH10PM-5A, and AH20MC-5A. 5-153 Error Troubleshooting The motion control function block conflicts with other motion control function blocks. Make sure that other uniaxial motion control function blocks are not started or the execution of other uniaxial motion control function blocks is complete before the motion control function block is started.