Chapter 5 Applied Instructions 4. Example The motion control function block T_TrSeg2 is used to insert two-speed motion which is triggered by a transition in DOG’s signal from low to high. The motion control function block named T_TrSeg2_U1 is set so that the first axis moves at a speed of 3,000 pulses per second, and will move for 2,000 pulses at a speed of 1,000 pulses per second after a transition in DOG’s signal from low to high. Execute 1 t 0 Busy 0 1 t Done 1 t Motion 0 Velocity 3000 1000 0 t Position (Rising edge-trigger) 2000 Dog t t After the first axis moves for 2,000 pulses, Done will be set to True. 5.
Modules which are supported The motion control function block T_TrSeg2 supports AH05PM-5A, AH15PM-5A, AH10PM-5A, and AH20MC-5A. 5-161 Error Troubleshooting The motion control function block conflicts with other motion control function blocks. Make sure that other uniaxial motion control function blocks are not started or the execution of other uniaxial motion control function blocks is complete before the motion control function block is started.