AH500 Motion Control Module Manual 5.10.7 JOG Motion 1. Motion control function block The motion control function block T_Jog is used to start JOG motion. The value of the Axis input pin indicates an axis number, and the value of the Velocity input pin indicates the speed of JOG motion. If the value of the PositiveEnable input pin is set to True, positive JOG motion will be started. If the value of the NegativeEnable input pin is set to True, negative JOG motion will be started. 2.

Input pins/Output pins 5-162 Input pin Name Function Data Setting value Time when a value is valid type Axis Motion axis number WORD K1~K16 The value of the Axis input pin is valid when there is a transition in the Execute input pin’s signal from low to high. PositiveEnable Enabling positive JOG motion BOOL True/False  If the PositiveEnable input pin and the NegativeEnable input pin are set to True simultaneously, positive JOG motion will be enabled, and the NegativeEnable input pin will be reset to False.

 If the PositiveEnable input pin is set to True after the NegativeEnable input pin is set to True, the NegativeEnable input pin will be reset to False, the negative JOG motion will stop, and the positive JOG motion will be enabled.