AH500 Motion Control Module Manual The number of pulses per second is a unit for the Velocity input pin. Users can change the unit used by means of the motion control function block T_AxisSetting2. 3. Troubleshooting 4. Example The motion control function block T_Jog is used to start JOG motion. Positive JOG motion is enabled by EnableP, and negative JOG motion is enabled by EnableN. The first axis moves at a speed of 10,000 pulses per second. If EnableP is set to 1, the first axis will move in the positive direction. If EnableN is set to 1, the first axis will move in the negative direction.
5-164 Output pin Name Function Data type Time when there is Time when there is a transition in an output pin’s signal from high to low a transition in an output pin’s signal from low to high Aborted The execution of the motion control function block is interrupted by a command. BOOL The execution of the motion control function block is interrupted by a command. There is a transition in the Aborted output pin’s signal from high to low when there is a transition in the PositiveEnable input pin’s signal from high to low or when there is a transition in the NegativeEnable input pin’s signal from high to low.
If the PositiveEnable input pin and the NegativeEnable are set to False when the execution of the motion control function block is interrupted, the Aborted output pin will be set to False in the next cycle. Error An error occurs in the motion control function block. BOOL Input values are incorrect. The axis specified is in motion before the motion control function block is executed. There is a transition in the Error output pin’s signal from high to low when there is a transition in the PositiveEnable input pin’s signal from high to low or when there is a transition in the NegativeEnable input pin’s signal from high to low.
Error Troubleshooting The values of input pins in the motion control function block are incorrect. Check whether the values of the input pins are in the ranges allowed. The motion control function block conflicts with other motion control function blocks. Make sure that other uniaxial motion control function blocks are not started or the execution of other uniaxial motion control function blocks is complete before the motion control function block is started.