Chapter 5 Applied Instructions EnableP 1 t EnableN 0 1 0 t Busy 1 t Motion 0 Velocity 10000 0 t -10000 When EnableP is set to 1, the first axis moves at a speed of 10,000 pulses per second in the positive direction. When EnableN is set to 1, the first axis moves at a speed of 10,000 pulses per second in the negative direction. When EnableP and EnableN are not set to 1, the first axis stops moving. 5. Modules which are supported The motion control function block T_Jog supports AH05PM-5A, AH10PM-5A, AH15PM-5A, and AH20MC-5A. 5.10.8 Manual Pulse Generator Mode 1. Motion control function block The motion control function block T_MPG is used to enable a manual pulse generator mode.
The value of the Axis input pin indicates an axis number. The motion of the axis specified follows the operation of a manual pulse generator. The relation between the position of the axis specified and the input pulses generated by the manual pulses used is determined by the RatioNum input pin and the RatioDen input pin. Servo motor Frequency of input pulses X RatioNum RatioDen FP Servo drive B phase A phase = Frequency of output pulses RP 5-165