Mitsubishi — 5.10.8 Manual Pulse Generator Mode

AH500 Motion Control Module Manual Please refer to Chapter 2 for more information about wiring a manual pulse generator. 2. Input pins/Output pins 5-166 Input pin Name Function Data Setting value Time when a value is valid type Axis Motion axis number WORD K1~K16 The value of the Axis input pin is valid when there is a transition in the Enable input pin’s signal from low to high. Enable Manual pulse generator mode BOOL True/False - Reset Resetting the manual pulse generator used BOOL True/False The value of the Reset input pin is valid when there is a transition in the Enable input pin’s signal from low to high.

RatioNum Numerator of an electronic gear ratio WORD K0~K32,767 When the motion control function block is executed, the value of the RatioNum input pin is updated repeatedly. RatioDen Denominator of an electronic gear ratio WORD K1~K32,767 When the motion control function block is executed, the value of the RatioDen input pin is updated repeatedly. State of output pin Name Function Data type Time when there is Time when there is a transition in an output pin’s signal from high to low a transition in an output pin’s signal from low to high Valid An output value is valid.

BOOL  There is a transition in the Valid output pin’s signal from low to high when there is a transition in the Enable input pin’s signal from low to high.  There is a transition in the Valid output pin’s signal from high to low when motion stops.  There is a transition in the Valid output pin’s signal from high to low when there is a transition in the Error output pin’s signal from low to high.  There is a transition in the Valid output pin’s signal from high to low when there is a transition in the Aborted output pin’s signal from low to high.