Mitsubishi — 5.10.10 Stopping Uniaxial Motion

Chapter 5 Applied Instructions 3. Troubleshooting 4. Modules which are supported The motion control function block T_HomeReturn supports AH05PM-5A, AH15PM-5A, and AH10PM-5A. 5.10.10 Stopping Uniaxial Motion 1. Motion control function block The motion control function block T_AxisStop is used to stop the motion of the axis specified. The value of the Axis input pin indicates an axis number. 2. Input pins/Output pins 5-171 Error Troubleshooting The values of input pins in the motion control function block are incorrect. Check whether the values of the input pins are in the ranges allowed. The motion control function block conflicts with other motion control function blocks.

Make sure that other uniaxial motion control function blocks are not started or the execution of other uniaxial motion control function blocks is complete before the motion control function block is started. Input pin Name Function Data Setting value Time when a value is valid type Axis Motion axis number WORD K1~K16 The value of the Axis input pin is valid when there is a transition in the Execute input pin’s signal from low to high. Execute Motion is stopped when there is a transition in the Execute input pin’s signal from low to high. BOOL True/False -