AH500 Motion Control Module Manual 2. Input pins/Output pins 5-184 Input pin Name Function Data Setting value Time when a value is valid type Axis Motion axis number WORD K1~K16 The value of the Axis input pin is valid when there is a transition in the Execute input pin’s signal from low to high. Execute The present position of an axis is written when there is a transition in the Execute input pin’s signal from low to high. BOOL True/False - Position Present position of the axis specified DWORD K-2,147,483,648~ K2,147,483,647 The value of the Position input pin is valid when there is a transition in the Execute input pin’s signal from low to high.
State of output pin Name Function Data type Time when there is Time when there is a transition in an output pin’s signal from high to low a transition in an output pin’s signal from low to high Done The execution of the motion control function block is complete. BOOL The writing of a position is complete. There is a transition in the Done output pin’s signal from high to low when there is a transition in the Execute input pin’s signal from high to low. If the Execute input pin is set to False when motion is complete, the Done output pin will be set to False in the next cycle. Busy The motion control function block is being executed.
BOOL There is a transition in the Busy output pin’s signal from low to high when there is a transition in the Execute input pin’s signal from low to high. There is a transition in the Busy output pin’s signal from high to low when there is a transition in the Done output pin’s signal from low to high. There is a transition in the Busy output pin’s signal from high to low when there is a transition in the Error output pin’s signal from low to high. Error An error occurs in the motion control function block. BOOL Input values are incorrect.
There is a transition in the Error output pin’s signal from high to low when there is a transition in the Execute input pin’s signal from high to low.