Chapter 5 Applied Instructions 3. Troubleshooting 4. Modules which are supported The motion control function block T_SetPosition supports AH05PM-5A, AH10PM-5A, AH15PM-5A, and AH20MC-5A. Note: To prevent errors from occurring, please avoid using the motion control function block to set the present position of the master axis involved in cam motion or gear motion. 5.10.16 Setting the Polarities of Input Terminals AH20MC-5A/AH10PM-5A AH15PM-5A AH05PM-5A 1. Motion control function block The motion control function block T_InputPolarity is used to set the polarities of the input terminals, and read the states of the input terminals in the AH500 series motion control module used.
Users can set the polarities of the input terminals in the AH500 series motion control module used by means of input pins, and read the states of the input terminals in the AH500 series motion control module by means of output pins. 2. Input pins/Output pins 5-185 Error Troubleshooting The values of input pins in the motion control function block are incorrect. Check whether the values of the input pins are in the ranges allowed. Input pin Name Function Data Setting value Time when a value is valid type Enable Enabling the setting of the polarities of the input terminals, and the displaying of the states of the input terminals in the AH500 series motion control BOOL True/False -