Chapter 5 Applied Instructions *1: Value of the Master input pin 5-193 State of output pin Name Function Data type Time when there is Time when there is a transition in an output pin’s signal from high to low a transition in an output pin’s signal from low to high CycleStartFlag Starting a cam cycle (The value of the CycleStartFlag output pin remains unchanged for one scan cycle.) BOOL A cam cycle begins There is a transition in the CycleStartFlag output pin’s signal from high to low in the scan cycle following a cam cycle. InCam The slave axis specified meshes with the master axis specified.
BOOL There is a transition in the InCam output pin’s signal from low to high when there is a transition in the CamOut input pin’s signal from low to high. There is a transition in the InCam output pin’s signal from high to low when there is a transition in the CamOut input pin’s signal from high to low. Value of output pin Name Function Data Output range Update type Index Index of a point DWORD K1~K2047 When the motion control function block is executed, the value of the Index output pin is updated repeatedly.
InputPulses Number of input pulses DWORD K-2,147,483,648~ K2,147,483,647 When the motion control function block is executed, the value of the InputPulses output pin is updated repeatedly. InputFreq Frequency of input pulses DWORD K0~K2,147,483,647 When the motion control function block is executed, the value of the InputFreq output pin is updated repeatedly. Value Definition 0 Manual pulse generator 1~16 Motion axis 1~motion axis 16 200 C200 204 C204 208 C208 212 C212 216 C216 220 C220