Mitsubishi — 5.10.19 Reading a Cam Point

AH500 Motion Control Module Manual 3. Troubleshooting 4. Modules which are supported The motion control function block T_CamIn supports AH05PM-5A, AH10PM-5A, AH15PM-5A, and AH20MC-5A. 5.10.19 Reading a Cam Point 1. Motion control function block The motion control function block T_CamRead is used to read a particular point in a cam chart. The value of the Axis input pin indicates an axis number. The value of the CamPoiontNo input pin indicates a cam point number. The value of the MasterPosition output pin indicates the position of the master axis specified, and the value of the SlavePosition output pin indicates the position of the slave axis specified. 2.

Input pins/Output pins 5-194 Error Troubleshooting The values of input pins in the motion control function block are incorrect. Check whether the values of the input pins are in the ranges allowed. Input pin Name Function Data Setting value Time when a value is valid type Axis Motion axis number WORD 1~16 The value of the Axis input pin is valid when there is a transition in the Enable input pin’s signal from low to high. Enable The reading of a cam point is enabled when there is a transition in the Enable input pin’s signal from low to high.

BOOL True/False - CamPointNo Cam point number DWORD K0~K2046 When the motion control function block is executed, the value of the CamPointNo input pin is updated repeatedly.