AH500 Motion Control Module Manual 3. Troubleshooting 4. Modules which are supported The motion control function block T_CamCurveUpdate supports AH05PM-5A, AH10PM-5A, AH15PM-5A, and AH20MC-5A. 5-204 enabled. State of output pin Name Function Data type Time when there is Time when there is a transition in an output pin’s signal from high to low a transition in an output pin’s signal from low to high Done The execution of the motion control function block is complete. BOOL There is a transition in the Done output pin’s signal when the update of a cam curve is complete.
There is a transition in the Done output pin’s signal from high to low when there is a transition in the Execute input pin’s signal from high to low. If the Execute input pin is set to False when the execution of the motion control function block is complete, the Done output pin will be set to False in the next cycle. Busy The motion control function block is being executed. BOOL There is a transition in the Busy output pin’s signal from low to high when there is a transition in the Execute input pin’s signal from low to high. There is a transition in the Busy output pin’s signal from high to low when there is a transition in the Error output pin’s signal from low to high.
There is a transition in the Busy output pin’s signal from high to low when there is a transition in the Done output pin’s signal from low to high. Error An error occurs in the motion control function block. BOOL Input values are incorrect. There is a transition in the Error output pin’s signal from high to low when there is a transition in the Execute input pin’s signal from high to low. Error Troubleshooting The values of input pins in the motion control function block are incorrect. Check whether the values of the input pins are in the ranges allowed.