Mitsubishi — 5.11.3 Stopping G-code Motion

AH500 Motion Control Module Manual 5.11.3 Stopping G-code Motion 1. Motion control function block The motion control function block T_GcodeStop is used to stop the execution of an Ox motion subroutine. 2. Input pins/Output pins 5-210 Input pin Name Function Data Setting value Time when a value is valid type Execute G-code motion is stopped when there is a transition in the Execute input pin’s signal from low to high. BOOL True/False - State of output pin Name Function Data type Time when there is Time when there is a transition in an output pin’s signal from high to low a transition in an output pin’s signal from low to high Done The execution of the function block is complete.

BOOL  There is a transition in the Done output pin’s signal from low to high when the stopping of G-code motion is complete.  There is a transition in the Done output pin’s signal from high to low when there is a transition in the Execute input pin’s signal from high to low.  If the Execute input pin is set to False when motion is complete, the Done output pin will be set to False in the next cycle. Busy The motion control function block is being executed. BOOL  There is a transition in the Busy output pin’s signal from low to high when there is a transition in the Execute input pin’s signal from low to high.

 There is a transition in the Busy output pin’s signal from high to low when there is a transition in the Error output pin’s signal from low to high.  There is a transition in the Busy output pin’s signal from high to low when there is a transition in the Done output pin’s signal from low to high.