Chapter 5 Applied Instructions FB1 Timing diagram: Execute 1 0 t Busy1 0 1 t 1 FB2 Done 0 t Enable1 1 0 t CLR 1 0 t Valid 1 t Busy2 1 0 0 t 5. Modules which are supported The motion control function block T_Mcode supports AH05PM-5A, AH10PM-5A, AH15PM-5A, and AH20MC-5A. 5.11.5 Multiaxial Absolute Linear Interpolation 1. Motion control function block The motion control function block T_AbsMoveLinear is used to start multiaxial absolute linear interpolation.
Users can set the axes which execute interpolation by means of the AxesGroup input pin, set the target positions of the axes specified by means of the Position input pin, and set the speed of the axes specified by means of the Velocity input pin. 2. Input pins/Output pins 5-215 Input pin Name Function Data Setting value Time when a value is valid type Execute Motion is started when there is a transition in the Execute input pin’s signal from low to high. BOOL True/False -