Mitsubishi — 5.11.6 Multiaxial Relative Linear Interpolation

AH500 Motion Control Module Manual 5-218 Input pin Name Function Data Setting value Time when a value is valid type Execute Motion is started when there is a transition in the Execute input pin’s signal from low to high. BOOL True/False - Distance Distances for which the axes specified move DWORD[6] [ , , , , , ] ______ K-2,147,483,648~ K2,147,483,647 The value of the Distance input pin is valid when there is a transition in the Execute input pin’s signal from low to high. Velocity Speed of interpolation DWORD K1~K2,147,483,647 The value of the Velocity input pin is valid when there is a transition in the Execute input pin’s signal from low to high.

State of output pin Name Function Data type Time when there is Time when there is a transition in an output pin’s signal from high to low a transition in an output pin’s signal from low to high Done The execution of the function block is complete. BOOL  There is a transition in the Done output pin’s signal from low to high when multiaxial relative linear interpolation is complete.  There is a transition in the Done output pin’s signal from high to low when there is a transition in the Execute input pin’s signal from high to low.  If the Execute input pin is set to False when motion is complete, the Done output pin will be set to False in the next cycle.

Busy The motion control function block is being executed. BOOL  There is a transition in the Busy output pin’s signal from low to high when there is a transition in the Execute input pin’s signal from low to high.  There is a transition in the Busy output pin’s signal from high to low when there is a transition in the Error output pin’s signal from low to high.  There is a transition in the Busy output pin’s signal from high to low when there is a transition in the Done output pin’s signal from low to high.