Chapter 5 Applied Instructions 5.13.7 Resetting High-speed Comparison 1. Motion control function block The motion control function block T_CmpOutRst is used to reset high-speed comparison, and check the comparison conditions used. CLR_Y08, CLR_Y09, CLR_Y010, CLR_Y011, CLR_C200Rst, CLR_C204Rst, CLR_C208Rst, and CLR_C212Rst determine the output devices which will be reset. 2. Input pins/Output pins 5-251 Input pin Name Function Data Setting value Time when a value is valid type Enable The motion control function block is enabled when there is a transition in the Enable input pin’s signal from low to high.
BOOL True/False - CLR Y08 _ Resetting the output devices Y0.8, Y0.9, Y0.10, Y0.11, C200, C204, C208, and C212 BOOL True/False When the motion control function block is executed, the values of these input pins are updated repeatedly. CLR Y09 _ CLR Y010 _ CLR Y011 _ CLR C200Rst _ CLR C204Rst _ CLR C208Rst _ CLR C212Rst _ State of output pin Name Function Data type Time when there is Time when there is a transition in an output pin’s signal from high to low a transition in an output pin’s signal from low to high Valid An output value is valid.
BOOL There is a transition in the Valid output pin’s signal from low to high when there is a transition in the Enable input pin’s signal from low to high. There is a transition in the Valid output pin’s signal from high to low when there is a transition in the Enable input pin’s signal from high to low.