AH500 Motion Control Module Manual 3. Troubleshooting 4. Modules which are supported The motion control function block T_CmpOutRst supports AH05PM-5A, AH10PM-5A, AH15PM-5A, and AH20MC-5A. 5.13.8 Setting High-speed Capture 5-252 State of output pin Name Function Data type Time when there is Time when there is a transition in an output pin’s signal from high to low a transition in an output pin’s signal from low to high Busy The motion control function block is being executed. BOOL There is a transition in the Busy output pin’s signal from low to high when there is a transition in the Enable input pin’s signal from low to high.
There is a transition in the Busy output pin’s signal from high to low when there is a transition in the Error output pin’s signal from low to high. There is a transition in the Busy output pin’s signal from high to low when there is a transition in the Enable input pin’s signal from high to low. Error An error occurs in the motion control function block. BOOL Input values are incorrect. The source specified has been occupied. There is a transition in the Error output pin’s signal from high to low when there is a transition in the Enable input pin’s signal from high to low.
Value of output pin Name Function Data Output range Time when a value is valid type CMP Y08 _ States of the output devices Y0.8, Y0.9, Y0.10, Y0.11, C200, C204, C208, and C212 BOOL True/False When the Valid output pin is set to True, the values of these output pins are updated repeatedly. CMP Y09 _ CMP Y010 _ CMP Y011 _ CMP C200Rst _ CMP C204Rst _ CMP C208Rst _ CMP C212Rst _ Error Troubleshooting The values of input pins in the motion control function block are incorrect. Check whether the values of the input pins are in the ranges allowed.