Chapter 5 Applied Instructions 3. Troubleshooting 4. Modules which are supported The motion control function block T_Capture supports AH05PM-5A, AH10PM-5A, AH15PM-5A, and AH20MC-5A. 5.13.9 High-speed Masking 1. Motion control function block The motion control function block T_CapMask is used to start high-speed masking. The MaskValue input pin determines the range which will be masked. 5-255 State of output pin Name Function Data type Time when there is Time when there is a transition in an output pin’s signal from high to low a transition in an output pin’s signal from low to high Error An error occurs in the motion control function block. BOOL Input values are incorrect.
The source specified has been occupied. There is a transition in the Error output pin’s signal from high to low when there is a transition in the Enable input pin’s signal from high to low. Value of output pin Name Function Data Output range Time when a value is valid type CapValue Value which is captured DWORD K-2,147,483,648~ K2,147,483,647 When the motion control function block is executed, the value of the CapValue of output pin is updated repeatedly. If there is no trigger, the value captured will remain unchanged. Error Troubleshooting The values of input pins in the motion control function block are incorrect. Check whether the values of the input pins are in the ranges allowed.
The capturer specified has been used. Use another capturer.