Mitsubishi — 5.13.11 Absolute Encoder

AH500 Motion Control Module Manual 3. Troubleshooting 4. Modules which are supported The motion control function block T_Interrupt supports AH05PM-5A, AH10PM-5A, AH15PM-5A, and AH20MC-5A. 5.13.11 Absolute Encoder 1. Motion control function block The motion control function block T_AbsEncoder is used to start the reading of the position of an absolute encoder. 5-258 State of output pin Name Function Data type Time when there is Time when there is a transition in an output pin’s signal from high to low a transition in an output pin’s signal from low to high Valid An interrupt is enabled.

BOOL  There is a transition in the Valid output pin’s signal from low to high when an interrupt is enabled.  There is a transition in the Valid output pin’s signal from high to low when there is a transition in the Enable input pin’s signal from high to low. Busy The motion control function block is being executed. BOOL  There is a transition in the Busy output pin’s signal from low to high when there is a transition in the Enable input pin’s signal from low to high.  There is a transition in the Busy output pin’s signal from high to low when there is a transition in the Error output pin’s signal from low to high.

 There is a transition in the Busy output pin’s signal from high to low when there is a transition in the Enable input pin’s signal from high to low. Error An error occurs in the motion control function block. BOOL  Input values are incorrect.  The source specified has been occupied.  There is a transition in the Error output pin’s signal from high to low when there is a transition in the Enable input pin’s signal from high to low. Error Troubleshooting The values of input pins in the motion control function block are incorrect. Check whether the values of the input pins are in the ranges allowed.