Mitsubishi — 5.13.11 Absolute Encoder

Chapter 5 Applied Instructions 2. Input pins/Output pins 5-259 Input pin Name Function Data Setting value Time when a value is valid type Channel Group number WORD K1~K4 (*1) The value of the Channel input pin is valid when there is a transition in the Enable input pin’s signal from low to high. Execute The reading of the position of an absolute encoder is enabled when there is a transition in the Execute input pin’s signal from low to high. BOOL True/False - Bit Resolution of an absolute encoder DWORD K1~K32 (*2) When the motion control function block is executed, the value of the Bit input pin is updated repeatedly.

State of output pin Name Function Data type Time when there is Time when there is a transition in an output pin’s signal from high to low a transition in an output pin’s signal from low to high Done The execution of the motion control function block is complete. BOOL  There is a transition in the Done output pin’s signal when the reading of the position of an absolute encoder is complete.  There is a transition in the Done output pin’s signal from high to low when there is a transition in the Execute input pin’s signal from high to low.  If the Execute input pin is set to False when motion is complete, the Done output pin will be set to False in the next cycle.

Busy The motion control function block is being executed. BOOL  There is a transition in the Busy output pin’s signal from low to high when there is a transition in the Execute input pin’s signal from low to high.  There is a transition in the Busy output pin’s signal from high to low when there is a transition in the Done output pin’s signal from low to high.  There is a transition in the Busy output pin’s signal from high to low when there is a transition in the Error output pin’s signal from low to high.  There is a transition in the Busy output pin’s signal from high to low when there is a transition in the Aborted output pin’s signal from low to high.