AH500 Motion Control Module Manual Velocity T ACC T DEC V MAX V(II) Time Start DOG 7.11 Status Flags and Status Registers 1. Ready flag [Description] There are ready flags for axes. For example, SM1048 is the ready flag for the first axis, SM1148 is the ready axis for the second axis, and SM1248 is the ready flag for the third axis. Users can judge whether an axis still operates by means of the flag for the axis. Description of SM1048: SM1048 is ON before the first axis operates. After the first axis begins to operate, SM1048 will be turned from ON to OFF. After the operation of the first axis is complete, SM1048 will b e turned from OFF to ON. 2.
Motion error flag [Description] If an error occurs in an axis, an error message will be stored in the register for the axis. If users want to eliminate the error occuring in an axis, they have to clear the error message stored in the register for the axis, and reset the motion error flag for the axis. 7-34 V(I) V BIAS (1+N)th axis HW LW - SM1048+100*N (1+N)th axis HW LW - SM1049+100*N