Chapter 8 Electronic Cam 8.2 Operation of an Electronic Cam Input sent by a master axis Electronic cam Output sent by a slave axis 8.2.1 Initial Setting 8.2.1.1 Creating Electronic Cam Data There are two methods of creating electronic cam data. Method 1: Function that relates the positions of a master axis to the positions of a slave axis Method 2: Measuring the relation between the positions of a master axis and the positions of a slave axis at work Please refer to section 8.3 for more information. 8.2.1.2 Setting an Input/a Output Pulse Type 1. Setting an input pulse type The master axis specified can be a manual pulse generator, a motion axis, C200, C204, C208, C212, C216, or C220.
If users use a counter as a master axis, they have to set an input pulse type. They can set an input pulse type for the counter used by means of the motion control function block T_HCnt. 8-3 Pulses sent by (2) a master axis type input Setting pulse an (2) type output Setting Output pulse an (2) type input Setting pulse an Motion control module (3) cam by Pulses cam by Pulses a a slave master sent sent (1) Cam data (Resolution:
10~2048) (3) Starting a cyclic electronic cam (2) type output Setting pulse an Step 1 Step 2 Step 3 Initial setting Setting a master axis and a slave axis Starting/Stopping an electronic cam Creating electronic cam data (1) Setting an input /a output pulse type (2) Setting a master axis (3) Setting the starting angle of the master axis specified (3) Setting a slave axis (3) Starting/Stopping a cam which operates cyclically (3)