Mitsubishi — 8.2.1.2 Setting an Input/a Output Pulse Type

AH500 Motion Control Module Manual 2. Value of the InputType input pin 3. Setting an output pulse type If a pulse-type motion controller (an AH10PM series motion control module) is used to execute cam motion, an output pulse type has to be set. If a communication-type motion controller is used to execute cam motion, no output pulse type needs to be set. User can set an output pulse type by means of the motion control function block T_AxisSetting2 4.

Value of the OutputType input pin 8-4 Input Input type (positive logic) Description value mcUD (0) FP Clockwise pulses RP Counterclockwise pulses Counting up/down mcPD (1) FP Pulses RP Directions Counterclockwis e Clockwise Pulses+Directions mcAB (2) FP A-phase pulses RP B-phas e pulses Clockwise Counterclockwis e A/B-phase pulses mc4AB (3) FP A-phase pulses RP B-phase pulses Clockwise Counterclockwise Four times the frequency of A/B-phase pulses Input Output type (positive logic) Description value mcUD (0) FP Clockwise pulses RP Counterclockwise pulses Counting up/down mcPD (1) FP Pulses RP Directions Counterclockwis e Clockwise Pulses+Directions mcAB (2) FP A-phase pulses RP B-phase pulses Clockwise Counterclockwise A/B-phase pulses mc4AB (3)