AH500 Motion Control Module Manual 5. Stopping electronic cam motion by means of the Enable input pin If the Enable input pin is set to True, the slave axis specified will mesh with the master axis specified. If the Enable input pin is reset to OFF, the slave axis specified will not mesh with the master axis specified, and the InCam output pin will be set to False. If the Enable input pin is set to True again, the slave axis specified will mesh with the master axis specified. Displacement of the slave axis Position of the master axis Starting an electronic cam operating cyclically ( E nable input pin) The slave axis specified meshes with the master axis specified.
( InCam output pin) If the Enable input pin is set to True, the slave axis specified will mesh with the master axis specified. If the Enable input pin is set to False after the CycleStop input pin is set to True, cam motion stops when a cycle is complete, and the InCam output pin is False when the cam motion stops. If the Enable input pin is set to True again, the slave axis specified will mesh with the master axis specified. Displacement of the slave axis Starting an electronic cam operating cyclically ( Position of the master axis E nable input pin) Stopping a whole cycle ( CycleStop input pin) The slave axis specified meshes with the master axis specified. ( InCam output pin) 8-10