Chapter 8 Electronic Cam 8.2.3.2 Stopping an Electronic Cam Operating Cyclically Users can stop an electronic cam by means of the Enable input pin and the CamOut input pin in the motion control function block T_CamIn. 1. Value of the CamOut input pin 2. Value of the CycleStop input pin 3. Value of the InCam output pin 4. Stopping electronic cam motion by means of the CamOut input pin If the CamOut input pin is set to True when the Enable input pin is True, the slave axis specified will not mesh with the master axis specified, and the InCam output pin will be set to False.
If the CamOut input pin is reset to False, the slave axis specified will mesh with the master axis specified, and the InCam output pin will be set to True. Displacement of the slave axis Starting an electronic cam operating cyclically ( Position of the master axis Not meshing with the master axis specified ( E nable input pin) CamOut input pin) The slave axis specified meshes with the master axis specified. ( InCam output pin) 8-9 Input value Definition Description True/False Not meshing with the master axis specified If the CamOut input pin is set to True, the slave axis specified will not mesh with the master axis specified.
Input value Definition Description True/False Stopping a whole cycle If the CycleStop input pin is set to True when the Enable input pin is reset, cam motion will not stop until a cycle is complete. Output value Definition Description True/False The slave axis specified meshes with the master axis specified. If the slave axis specified meshes with the master axis specified, the InCam output pin will be set to True