Mitsubishi — 8.2.3.1 Starting an Electronic Cam Operating Cyclically

AH500 Motion Control Module Manual 8.2.3.1 Starting an Electronic Cam Operating Cyclically After users set a master axis, a slave axis, and a starting angle by means of input pins in the motion control function block T_CamIn, electronic cam motion will be started if the Enable input pin is set to True. 1. Value of the CycleStartFlag output pin The steps of starting an electronic cam which operates cyclically are as follows.  At the time T1, the Enable input pin is set to True (an electronic cam which operates cyclically is started).  After the time T2 elapses, the CycleStartFlag output pin will be set to True. The value of the CycleStartFlag output pin will be cleared after one scan cycle.

 During the time T3, the initialization of the electronic cam is complete, the electronic cam operates cyclically, and the motion of the slave axis specified follows the motion of the master axis specified in accordance with the electronic cam data created. n n+60 n+300 Displacement of the slave axis Position of the master axis an electronic cam operating cyclically ( Starting E nable input pin) CycleStartFlag output pin) Starting a cam cycle ( T1 T2 T3 Reset automatically 8-8 Output value Definition Description True/False Starting a cam cycle When the output pin is set to True, a cam cycle begins. The value of the CycleStartFlag output pin remains unchanged for one scan cycle.