AH500 Motion Control Module Manual electronic cam chart created, and closing the Data Setting window Cancel : Closing the Data Setting window. Initial Setting : Setting the initial position of the slave axis After the users click “Export” in the CAM Chart-0 window, the displacement chart, the velocity chart, and the acceleration chart in the CAM Chart-0 window will be saved in the CAMData folder in the folder in which PMSoft is installed. There are three files in the CAMData folder. \CAMData\Data_S.txt: Displacement \CAMData\Data_V.txt: Velocity \CAMData\Data_A.txt: Acceleration Data_S.txt, Data_V.txt, and Data_A.txt are shown below. Displacement chart Path:
\CAMData\Data_S.txt Velocity chart Path: \CAMData\Data_V.txt Acceleration chart Path: \CAMData\Data_A.txt 8-14