Chapter 8 Electronic Cam Data Setting window after the Data Setting window is opened. If users click the Apply B-spline checkbox in the data setting area, B-spline will be automatically selected in the Data Setting window. Import : Importing the description of the relation between the master axis and the slave axis in terms of displacement Export : Exporting the description of the relation between the master axis and the slave axis in terms of displacement Import Speed Data : Importing the description of the relation between the master axis and the slave axis in terms of speed After the users click Data Setting… in the CAM Chart-0 window, the Data Setting window will appear.
The Data Setting window is composed of sections. The users can set a section of a cam curve in every section. A complete cam curve is composed of several sections. The users can set 360 sections at most. An electronic cam cycle is composed of the sections created by the users. Users can define the relation between the master axis and the slave axis in every section. Master Axis : Users can set the displacement of the master axis. A pulse is a unit of the measurement for displacement. The values that the users type in the Master Axis (pulse) column must be greater than 0, and must be in numerical order. Slave Axis : Users can set the displacement of the master axis.
A pulse is a unit of the measurement for displacement. The values that the users type in the Slave Axis (pulse) column can be positive values or negative values. CAM Curve : The functions which can be selected are Const Speed , Const Acc. , Single Hypot. , Cycloid , and B-Spline . If users click the Apply B-spline checkbox in the CAM Chart-0 window, B-spline will be automatically selected in the Data Setting window. Resolution : Users can set the number of data points used in a section. The number of data points must be in the range of 10 to 2047. If the users do not set resolutions for sections, the number of data points left will be equally distributed to the sections.
The users have to set resolutions according to equipment’s requirements. The higher the resolutions set are, the more smoothly the equipment used operates. Besides, the size of the electronic cam data gotten is big if the resolutions set are high. After sections of a cam curve are created, users can click Save , Load , Clear , Draw , OK , Cancel , or set the initial position of the slave axis. Save : Saving the data set in sections Load : Loading the data which was saved Clear : Clearing all the data in sections Draw : Compiling the data set in sections, and drawing the electronic cam data gotten on the electronic cam chart created OK :
Compiling the data set in sections, drawing the electronic cam data gotten on the 8-13