AH500 Motion Control Module Manual =>G01 X100.0 Y300.0 F500.0; G02 G00 X100.0 G03 G01 Y300.0 F500.0; =>G01 Y300.0 F500.0; If G00 is used, users do not have to set a velocity. Example: G00 X100.2 Y500.0; The speeds at which the axes move are the maximum speeds set in the AH500 series motion control module used. G00 and G01 can be extended to the next line. N0000 G00 X500.0 Y125.0; N0001 X-400.0 Y-500.0; =>G00 X-400.0 Y-500.0; N0002 G01 X100.0 Y25.0 F200.0; N0003 X-200.0 Y50.0; =>G01 X-200.0 Y50.0 F200.0; The speed parameter F for G01/G02/G03 can be extended to the next line.
(Users must specify the value of the speed parameter F in the first line.) N0000 G01 X500.0 Y125.0 F200.0; N0001 G03 X-40.0 Y-50.0 R100.0; =>G03 X-40.0 Y-50.0 R100.0 F200.0; N0002 G02 X100.0 Y25.0 I400.5 F200.0; N0003 G01 X-200.0 Y50.0; =>G01 X-200.0 Y50.0 F200.0; G90 and G91 have high priority over the other G-codes. G90 G01 X100.0 Y300.0 F500.0; =>G90 G01 X100.0 Y300.0 F500.0; G01 G90 X100.0 Y300.0 F500.0; =>G90 G01 X100.0 Y300.0 F500.0; Whether there are spaces in a program code, the program code can be identified. G01G91X500.0 Y125.0F200.0; =>G01 G91 X500.0 Y125.0 F200.0; Coordinates and speeds are converted into 32-bit values.
G01 X-125.5 F200.0; =>G01 X-125500 F200000; If the value of a parameter is a floating-point constant, it will be converted into an integer after it is multiplied by 1000. G01 X100 Y-125.5 F200.0; =>G01 X100 Y-125500 F200000; Parameter X for G04: A second is a unit of measurement for dwell duration. Parameter P for G04: A millisecond is a unit of measurement for dwell duration. In the example below, the system used automatically ignores 9 in P2509. G04 X4.5 (Dwell duration: 4.5 seconds) G04 X5 (Dwell duration: 5 seconds) G04 P4500 (Dwell duration: 4.5 seconds) G04 P2509 (Dwell duration: 2.5 seconds) The G-codes not supported are ignored and not read.
G21G54G01 X-125.5 F200.0; =>G01 X-125500 F200000; G43G87G96 X250.5 F200.0; =>G01 X250500 F200000; The writing of instructions conforms to the writing of general G-codes. Users can arrange the parameter marks used in any order. G0 X4.5 Z40.0 Y30.5 F200.2; =>G00 X4.500 Y30.500 Z40.000 F200.200; Z100.5Y400.0X300.0; =>G00 X300.000 Y400.000 Z100.500; G1xd100zd300y200.45 fd400; =>G01 XD100 Y200.450 ZD300 FD400; G3 ZD100 I200.0F50.60XD300 m80; =>G03 XD300 ZD100 I200.000 F50.600 M80; G03 yD100 x9999.9Z200.0r777.7 Fd800; =>G03 X9999.900 YD100 Z200.000 R777.700 FD800; 9-4