Chapter 9 Multiaxial Interpolation 9.4 Descriptions of G-code Instructions G-code 0000 Description: P 1 : Target position of an x-axis; P 2 : Target position of a y-axis; P 3 : Target position of a z-axis; P 4 : Target position of an A-axis; P 5 : Target position of a B-axis; P 6 : Target position of a C-axis If the value of a parameter is not a floating-point value, it must be in the range of -2,147,483,648 to 2,147,483,647. If the value of a parameter is a floating-point value, it must be in the range of-2,147,483.648 to 2,147,483.647. Users do not need to set the speeds at which the axes used moves. The speed at which an axis moves is its maximum speed.
Users only need to specify one target position or more than one target position. Operation Velocity Maximum speed Start-up speed Time Time it takes for the axis specified to decelerate Time it takes for the axis specified to accelerate Users can set the time it takes for an axis specified to accelerate/decelerate and the start-up speed of the axis by means of special data registers. The time it takes for an axis specified to accelerate/decelerate is proportional to the maximum speed of the axis.
9-5 Instruction code Operand Function G00 X P Y P Z P A P 1 2 3 4 B P C P 5 6 Rapid positioning Device K 16# F D DD W WW P 1 P 2 P 3 P 4 P 5 P 6 Number of pulses output