Mitsubishi — 11.4 Capture

Chapter 11 High-speed Capture and Compare Function 11.4 Capture  Control X0.0 Module number Control register number Initial device number Number of values  Definitions  Reading X0.0 Module number Control register number Initial device number Number of values  Definitions 11-9 TO K253 K1 S N Device Control Setting S Initial group number n (n=0~7) S +1 0 (S , S ) +3 +2 Control registers whose group number is n (S , S ) +5 +4 Data registers whose group number is n (S , S ) +7 +6 Control registers whose group number is n+1 (S , S ) +9 +8 Data registers whose group number is n+1 : :

(S , S ) +31 +30 Control registers whose group number is n+7 (S , S ) +33 +32 Data registers whose group number is n+7 S +50 Number of devices=2+m*4 m=Number of groups (8 groups at most can be used.) FROM K253 K1 S N Device Counter Status Reading S Initial group number n (n=0~7) S +1 0 (S , S ) +3 +2 Control registers whose group number is n (S , S ) +5 +4 Data registers whose group number is n (S , S ) +7 +6 Control registers whose group number is n+1 (S , S ) +9 +8 Data registers whose group number is n+1 : :

(S , S ) +31 +30 Control registers whose group number is n+7 (S , S ) +33 +32 Data registers whose group number is n+7 S +50 Number of devices=2+m*4 m=Number of groups (8 groups at most can be used.)