Mitsubishi — 12.4 Communication Function of PMSoft

AH500 Motion Control Module Manual  After users select an IP address, they can click Del or press DEL on the keyboard to delete the IP address from the list.  Users can select the number of times the sending of a command is retried if a connection error occurs in the Time of Auto-retry box, and select an interval of retrying the sending of a command in the Time Interval of Auto-retry box.  Steps of setting PMSoft Connect a computer to the Ethernet port on an AH500 series motion control module in the way described below, and then follow the steps described below. (1) Start PMSoft, and then click Communication Settings… on the Tools menu.

(2) Select a driver in the Driver drop-down list box. Before users create a connection between PMSoft and an AH500 series motion control module, they have to make sure that the driver is started in COMMGR. Select the Motion Controller option button, and click OK . The communication setting varies with the driver selected.    12-4