Chapter 13 Expansion Storage Device To restore, set bit 13 in SR214 to 0. To backup devices, set bit15 in SR214 to 1. M1 For example, if the value in SR214 is 8000H, the file \AHMotion\Device\0.csv in a memory card will be restored to the motion control module. 13.5 Program Backup and Restoration 13.5.1 Backup The operation for a program backup is described below, 1. Monitor an AH500 series motion control module by PMSoft, and stop the operation under the monitoring. Alternatively, set SM072 to 0 to stop O100. 2. Set SR214 by a device monitoring table or external communication. Set bit 12~bit 0 in SR214 to bit 0. The values of bit 12~bit 0 in SR214 represent a backup file name.
To backup, set bit 13 in SR214 to 1. To backup the program in the AH500 series motion control module, set bit 14 in SR214 to 1. After the program backup is completed, a .raw file which includes the password for the backup program will be generated in \AHMotion\Program\ in a memory card. The table above shows that the name of the .raw file is 0.raw. 13-7 MOV H8000 SR214