AH500 Motion Control Module Manual Introduction of the parameters SR1072, SR1172, SR1272, SR1372, SR1472, SR1572, SR1672, SR1772, SR1872, SR1972, SR2072, SR2172, SR2272, SR2372, SR2472, SR2572: Command sent to the servo drive for the axis specified on a DMCNET [Description] Usage of the registers: Setting the servo drive used to OFF/ON: User can set the servo drive used to OFF or ON. After the servo drive used is set, the status of the servo drive will be shown by a special data register. Resetting NMT: The servo drive used can be instructed to reset DMCNET communication. DMCTNET communication can be reset, whether the servo drive used is connected. Resetting an error flag:
After an error occurs in the servo drive used, users can reset the error flag for the error. The error flag for the error occurring in a servo drive can be reset only when the servo drive is connected. Writing the value of a 16-bit/32-bit parameter into the servo drive used: The servo drive used determines whether a parameter is a 16-bit parameter or a 32-bit parameter. When the value of a parameter in the servo drive used is read, it is not necessary to consider whether the parameter is a 16-bit parameter or a 32-bit parameter. A DMCNET can be used to instruct the servo drive used to return home, and can be used to set a DMCNET motion mode.
If a DMCNET is used to instruct a servo drive to return home, users have to set the mode of returning home. After a DMCNET is used to set a DMCNET motion mode, users have to control a servo drive by means of uniaxial motion.
14-4 1st axis 2nd axis 3rd axis 4th axis HW LW HW LW HW LW HW LW - SR1072 - SR1172 - SR1272 - SR1372 5th axis 6th axis 7th axis 8th axis HW LW HW LW HW LW HW LW - SR1472 - SR1572 - SR1672 - SR1772 9th axis 10th axis 11th axis 12th axis HW LW HW LW HW LW HW LW - SR1872 - SR1972 - SR2072 - SR2172 13th axis 14th axis 15th axis 16th axis HW LW HW LW HW LW HW LW - SR2272 - SR2372 - SR2472 - SR2572 Value Command sent to the servo drive for Value Command sent to the servo drive for (Hex) the axis specified on a DMCNET (Hex) the axis specified on a DMCNET Setting the servo drive used to OFF x1xx Writing the value of a 16-bit paramete into the servo drive used xxx1 Setting the servo drive used to ON x2xx Writing the value of a 32-bit paramete into the servo drive used xxx2 Resetting NMT x3xx Reading the value of a parameter in the servo drive used xxx3 Resetting an error flag x4xx Instructing the servo drive used to return home by means of a DMCNET xxx4 x5xx Setting a DMCNET motion mode by means of DMCNET