AH500 Motion Control Module Manual 3-24 Applicable model*1 OFF STOP RUN SR Function Attribute Latching Default number 05M 15M 10M 20M ON RUN STOP Maximum speed (V ) at which the MAX mn06 axis specified rotates (Low word) ○ ○ ○ ○ - - - R/W NO 500K Maximum speed (V ) at which the MAX mn07 axis specified rotates (High word) Start-up speed (V ) at which the BIAS mn08 axis specified rotates (Low word) ○ ○ ○ ○ - - - R/W NO 0 Start-up speed (V ) at which the BIAS mn09 axis specified rotates (High word) JOG speed (V ) JOG at which the axis mn10 specified rotates (Low word) ○ ○ ○ ○ - - - R/W NO 5000 JOG speed (V ) JOG at which the axis mn11 specified rotates (High word) Speed (V ) at RT which the axis mn12 specified returns home (Low word) ○ ○ ○ ○ - - - R/W NO 50K Speed (V ) at RT which the axis mn13 specified returns home (high word) Speed (V ) to CR which the speed of the axis specified mn14 decreases when the axis returns home (Low word) ○ ○ ○ ○ - - - R/W NO 1000 Speed (V ) to CR which the speed of the axis specified mn15 decreases when the axis returns home (High word) mn16 Number of PG0 pulses for the axis specified ○ ○ ○ ○ - - - R/W NO 0 mn17 Supplementary pulses for the axis specified ○ ○ ○ ○ - - - R/W NO 0 mn18 Home position of the axis specified (Low word) ○ ○ ○ ○ - - - R/W NO 0