Chapter 2 Specifications and System Configuratio n AH10PM-5A 2-76 Specifications Item AH10PM-5A Number of axes 6 axes Storage The capacity of the built-in storage is 64K steps. Unit Motor unit Compound unit Mechanical unit Users can set the initial register involved in the data exchange in a CPU Connection with a CPU module, and the number of registers involved in the data exchange in the module CPU module. Four hundred data registers at most can be involved in the data exchange. There are three types of pulse output modes. These modes adopt the differential output. Motor control 1. Pulse/Direction 2. Counting up/Counting down 3. A/B-phase output Single axis:
1M PPS Maximum speed Multi-axis interpolation: 1M PPS Operating STOP/RUN (automatic/manual switch) switch Input signal X0.8, X0.9, X0.10, X0.11, X0.12, X0.13, X0.14, X0.15, X0.0+, X0.0-, X0.1+, Detector X0.1-, X0.2+, X0.2-, X0.3+, and X0.3- Servo Y0.0+, Y0.0-, Y0.2+, Y0.2-, Y0.4+, Y0.4-, Y0.6+, Y0.6-, Y0.1+, Y0.1-, Y0.3+, Output signal output Y0.3-, Y0.5+, Y0.5-, Y0.7+, Y0.7-, Y0.8, Y0.9, Y0.10, and Y0.11 signal External communication Mini USB port port Ethernet port Mini SD card Expansion storage device The maximum capacity is 32 GB. Number of basic 27 instructions Number of applied 130 instructions OX0~99 (motion subroutine/positioning program): M02 (The execution of the program stops.
(END)) M-code M00~M01, M03~M101, and M103~M65535: The execution of the program pauses. (WAIT) Users can use them freely. G0 (rapid positioning), G1 (linear interpolation), G2 (circular interpolation, clockwise), G3 (circular interpolation, counterclockwise), G4 (dwell), G17 (XY G-code plane selection), G18 (ZX plane selection), G19 (YZ plane selection), G90 (absolute programming), and G91 (incremental programming) Weight 220g