Delta Electronics AH500 — 6.6.3 Connection Test

AH500 Operation Manual The Enter Present Value window is described below.  Message  Users can type a value in the Present Value box.  Name of a device or a symbol whose present value will be changed  Users can type a 16-bit value or a 32-bit value.  Value change history (Format: Device name Value)  In the binary mode, users can set the states of the bits through the mouse.  The setting values will be applied after OK is clicked. The window will be closed after Cancel is clicked.  Users can display or hide the binary mode. In this example, X0.0~X0.15 and Y0.0~Y0.15 are input devices and output devices assigned to the digital I/O module AH16AP11R-5A.

After the parameters in the hardware are downloaded to the CPU module, the states of X0.0~X0.15 will be the same as the states of the inputs on the actual module. Even if users set X0.0~X0.15 to ON or OFF in the program editing window, the states of X0.0~X0.15 will be updated by the actual input signals. However, an input contact can be forced ON or OFF during a test. Users can click an input contact or output contact which will be set, right-click the contact, point to Force on the context menu, and select On (X/Y) , Off (X/Y) , Release (X/Y) , or Release All . If an input contact or output contact is forced ON or OFF, a lock symbol will appear at the left side of the contact.

6-30 Force Description On (X/Y) Forcing the input contact or output contact selected ON