Chapter 8 Hardware Configuration The description of the columns in a table is as follows. If the color of a table cell is gray, the cell can not be edited. Description The parameter names or descriptions are shown in this column. Address Users can set data registers in this column. The parameters in the module which do not need to be updated constantly are stored in the data registers. If users specify data registers for the parameters in the module, and the parameters in HWCONFIG are downloaded to the CPU module correctly, the data registers in the CPU module are synchronized to the parameters in the module when the system operates.
As a result, the users can access the module through the data registers. Accessing a module through the data registers is more efficient than accessing the module through the instruction FROM/TO. Besides, the number of data registers that a module has is limited. When users set data registers, they have to refer to the instructions for the module. While assigning the data registers, it is recommended to set it as latched. If it is not set as latched, the parameters on the module will be cleared when power-on and an unexpected error will occur. As the example below shows, D3000 corresponds to the parameter CH0 Average Time in the Parameter Setting window for AH04AD-5A.
After the parameters in HWCONFIG are downloaded to the CPU module, users can change the value of the parameter CH0 Average Time by changing the value in D3000 in the CPU module. Besides, if users write a value which is not allowed by a parameter into a data register during the operation of the system, the system will restore the value in the data register and the value of the parameter to the original values. *. Please refer to programming manuals for more information about the instruction FROM/TO. If users want to set a data register, they can click in the Address cell for a parameter, and type a data register address which will be used in the Address window.
Please notice that a data register address which has been assigned to the module can not be used. If users want to delete the data register address in the Address cell for a parameter, they can open the Addr ess window in the same way, and delete the data register address in the window. If the color of the Address cell for a parameter is gray, users can not set a data register for the parameter. In the example below, the values of these parameters are binary values. The states of certain bits in the data register set in the Address cell for the first parameter correspond to these parameters.
Please refer to the documents for the modules for more information about the relation between parameters and the states of the bits in data registers. 8-54