Chapter 12 Troubleshooting 12-7 Error Description Remedy code 16#0033 The communication setting of COM1 is incorrect. (SM9) 1. Check the program and the related special data registers. 2. Set the communication port parameter for the CPU module in HWCONFIG again. 16#0034 The setting of the station address of COM1 is incorrect. (SM9) 1. Check the program and the related special data registers. 2. Set the communication port parameter for the CPU module in HWCONFIG again. 16#0035 The setting of the communication type of COM1 is incorrect. (SM9) 1. Check the program and the related special data registers. 2. Set the communication port parameter for the CPU module in HWCONFIG again.

16#0038 The communication setting of COM2 is incorrect. (SM9) 1. Check the program and the related special data registers. 2. Set the communication port parameter for the CPU module in HWCONFIG again. 16#0039 The setting of the station address of COM2 is incorrect. (SM9) 1. Check the program and the related special data registers. 2. Set the communication port parameter for the CPU module in HWCONFIG again. 16#003A The setting of the communication type of COM2 is incorrect. (SM9) 1. Check the program and the related special data registers. 2. Set the communication port parameter for the CPU module in HWCONFIG again. 16#0066 An error occurs when the system is backed up. 1.

Check whether the memory card is normal, and whether the capacity of the memory card is large enough. 2. Retry the backup procedure. If the error still occurs, please contact the factory. 16#0067 The length of the restored system parameters exceeds the length of the CPU module system parameters. This error code is a warning code. 16#2000 There is no END in the program in the PLC. (SM5) 1. Compile the program again, and download the program again. 2. Reinstall ISPSoft, compile the program again, and download the program again. 16#2002 GOEND is used incorrectly. (SM5) Check the program, compile the program again, and download the program again.

16#2003 The devices used in the program exceed the range. (SM0/SM5) Check the program, compile the program again, and download the program again. 16#2004 The part of the program specified by the label used in CJ/JMP is incorrect, or the label is used repeatedly. (SM0/SM5) Check the program, compile the program again, and download the program again. 16#2005 The N value used in MC is not the same as the corresponding N value used in MCR, or the number of N values used in MC is not the same as the number of N values used in MCR. (SM5) Check the program, compile the program again, and download the program again.

16#2006 The N values used in MC do not start from 0, or the N values used in MC are not continuous. (SM5) Check the program, compile the program again, and download the program again.