AH500 Programming Manual API 0305 Symbol: S : Data source Word/Double word D : Data destination Word/Double word n : Data length Word/Double word Explanation: 1. When the instruciton is executed, the data in S is transferred to the n devices starting from the device specified by D . When the instruction is not executed, the data in D is unchanged. 2. Only the 32-bit instructions can use the 32-bit counter. 3. The operand n used in the instruction NMOV should be within the range between 1 and 256, and the operand n used in the instruction DNMOV should be within the range between 1 and 128. D S S D+1 S D+2 N=5 S D+3 S D+4 Example: When M0 is ON, 100 is transferred to D0~D9.

6-124 Instruction code Operand Function D NMOV P S, D, n Transferring the data to several devices Device X Y M S T C HC D L SM SR E PR K 16# “$” DF S             D           n            Pulse instruction 16-bit instruction (7 steps) 32-bit instruction (7 steps) AH500 AH500 AH500 S