Delta AH500 — 2.2.8 Refresh Time of Special Auxiliary Relays

Chapter 2 Devices 2-45 Limited Special auxiliary Refresh time to relay SM690~SM691 Users set the flag to ON or OFF. SM692 SM692 is refreshed when the instruction HKY is executed. SM693 SM693 is refreshed when the instruction SEGL is executed. SM694 SM694 is refreshed when the instruction DSW is executed. SM695 Users set the flag to ON or OFF. AH5×0 SM699 1. The flag is refreshed after the Ether link parameters/data exchange parameters are downloaded. 2. The flag is refreshed after the system restoration is executed. AH5×1 1. The flag is refreshed after the Modbus TCP data exchange table is downloaded. 2. The flag is refreshed after the system restoration is executed. AH5×0 SM700-SM827 1.

The flag is refreshed after the data exchange parameters are downloaded. 2. The flag is refreshed every scan cycle. AH5×1 Users set the flag to ON or OFF. SM828-SM955 1. The flag is refreshed after the data exchange parameters are downloaded. 2. The flag is refreshed every scan cycle. SM1000 Users set the flag to ON or OFF. SM1090 SM1090 is ON when the TCP connection is busy. SM1091 SM1091 is ON when the UDP connection is busy. SM1100 The flag is refreshed when API 2200/API 2201/API 2202/API 2203/API 2204/API 2205 is executed or the network cable is reconnected. SM1106 SM1106 is ON when the PHY initialization fails.

SM1107 SM1107 is ON when the IP address, the netmask address, and the gateway address are set incorrectly. SM1108 SM1108 is ON when there is a filter setting error. SM1109 SM1109 is ON when the function of the socket is enabled and the same port is used. SM1112 SM1112 is ON when there is a setting error. SM1113 SM1113 is ON when there is a server error. SM1116 SM1116 is ON when the trigger of the PLC parameter is enabled. SM1117 SM1117 is ON when the trigger of the PLC parameter is triggered. SM1118 SM1118 is ON when the trigger is enabled and no mail has been sent. SM1119 SM1119 is ON when the trigger is enabled and the last mail has been sent successfully.

SM1120 SM1120 is ON when the trigger is enabled and the last mail has been sent in error. SM1121 SM1121 is ON when the trigger is enabled and the mail has been sent. SM1122 SM1122 is ON when the trigger is enabled and there is an SMTP server response timeout. SM1123 SM1123 is ON when the trigger is enabled and there is an SMTP server response error. SM1124 SM1124 is ON when the trigger is enabled and the size of the attachment exceeds the limit. SM1125 SM1125 is ON when the trigger is enabled and the attachment is not found. SM1126 SM1126 is ON when the trigger of the PLC parameter is enabled. SM1127 SM1127 is ON when the trigger of the PLC parameter is triggered.