BLTCON0 040 W A Blitter control register 0 BLTCON1 042 W A Blitter control register 1 These two control registers are used together to control blitter operations. There are two basic mode, area and line, which are selected by bit 0 of BLTCON1, as shown below.
AREA MODE ("normal") BIT BLTCON0 BLTCON1 15 ASH3 BSH3 14 ASH2 BSH2 13 ASH1 BSH1 12 ASA0 BSH0 11 USEA X 10 USEB X 09 USEC X 08 USED X 07 LF7 X 06 LF6 X 05 LF5 X 04 LF4 EFE 03 LF3 IFE 02 LF2 FCI 01 LF1 DESC 00 LF0 LINE(0) ASH 3-0 Shift value of A source BSH 3-0 Shift value of B source USEA Mode control bit to use source A USEB Mode control bit to use source B USEC Mode control bit to use source C USED Mode control bit to use destination D LF 7-0 Logic function minterm select lines EFE Exclusive fill enable IFE Inclusive fill enable FCI Fill carry input DESC Descending (decreasing address) control bit LINE Line mode control bit (set to 0) - Appendix A 261 -