AS Series Module Manual _6 Note: When using PID parameters to set up control registers: PID control registers of AS04TC-A and RTD-A are retainable; however PID control registers of AS06RTD-A and AS08TC-A are not retainable. PID formula: 1. When the PID_MODE is set to 0, the mode is set to auto: Independent Formula & Derivative of E ( PID_EQ=False & PID_DE=False ) 6-32 CR# Operand Function Description Range CH1 CH2 CH3 CH4 CH5 CH6 CH7 CH8 624 625 654 655 684 685 714 715 744 745 774 775 804 805 834 835 I MV _ Accumulated integral value Floating-point format. The accumulated integral value is temporarily stored for reference.
When the MV is out of the range 0%–100%, the accumulated integral value in I MV is _ unchanged. -- 626 656 686 716 746 776 806 836 CYCLE Sampling time (TS) When this instruction is read, the PID algorithm is implemented according to the sampling time, and the MV is refreshed. If TS is less than 1, it is read as 1. If TS is larger than 1,000, it is read as 1,000. Unit: 100 ms 1