AS Series Module Manual (4) Setting up the data mapping table I: Input data (T O), Ex. Connection 1 is corresponding to PLC D3000~D3099. O: Output data (O T), Ex. Connection 1 is corresponding to PLC D2000~D2099. C: here corresponds to the configurations. You can edit the corresponding PLC addresses of input and output. After editing, you need to download the parameters to Rockwell PLC. 10 10-16 I/O Message Connection Instance Connection No.
Function Length Defaults Attribute Connection 1 Input (TO) 0x65 100 words D3000~D3099 Output (OT) 0x64 100 words D2000~D2099 Configuration 0x80 8 words Refer to the table below Connection 2 Input (TO) 0x67 100 words D3100~D3199 Output (OT) 0x66 100 words D2100~D2199 Configuration 0x81 8 words Refer to the table below Connection 3 Input (TO) 0x69 100 words D3200~D3299 Output (OT) 0x68 100 words D2200~D2299 Configuration 0x82 8 words Refer to the table below Connection 4 Input (TO) 0x6B 100 words D3300~D3399 Output (OT) 0x6A 100 words D2300~D2399 Configuration 0x83 8 words Refer to the table below Connection 5 Input (TO) 0x6D 100 words D3400~D3499 Output (OT) 0x6C 100 words D2400~D2499 Configuration 0x84 8 words Refer to the table below