Delta Electronics — 11.4.1.1. Scan List, Input Table and Output Table

Chapter 11 DeviceNet Master Scanner Module AS01DNET-A 11.4 Master /Slave Mode 11.4.1 Introduction of Master/Slave Mode AS01DNET-A can work as a DeviceNet master as well as slave with at most 4 AS01DNET modules connectable to the 11 right side of AS PLC. Running on the right of AS-series PLC, AS01DNET-A with AS-series PLC together constitutes the DeviceNet master or slave. When working in Master/Slave mode, AS01DNET-A is required to switch the function toggle (RTU- Master/Slave) to Master/Slave mode and the DeviceNet Builder of version 2.04 and above is used for the setup. For details about the setup, refer to Section 11.4.10.  As a master, AS01DNET-A can provide the following function.

 Supporting the Client function of Explicit message;  Supporting IO polling connection with slaves;  The network configuration software DeviceNet Builder provides graphic configuration interface.  Sending explicit messages to read and write the data in slave through the explicit message instruction DNETRW.  Automatically performing data exchange with the PLC module; users just need write a program for D register in the PLC without using FROM/TO instructions.  Offering 190 bytes of output data area and 190 bytes of input data area for exchanging data with the master.  As a slave, AS01DNET-A can provide the following function.

 Explicit message Server and Group 2 only server connection mode;  Polling connection;  Offering 200 bytes of input data area and 200 bytes of output data area for exchanging data with master;  Automatically exchanging data with the PLC. The user just need to write a program for D register in the PLC without using FROM/TO instruction. 11.4.1.1. Scan List, Input Table and Output Table 11-13 Item Description Figure Scan List Before AS01DNET-A module works, the scan list must be configured through the configuration software. The scan list stores slave information including node address, I/O type, I/O size and etc. for data exchange.

The scanner module manages the slaves in the scan list, makes a connection with slaves and exchange I/O data with them. For those slaves which have not been configured to the scan list, AS01DNET-A will not make a connection and I/O data exchange with them.