Chapter 11 DeviceNet Master Scanner Module AS01DNET-A 11.4 Master /Slave Mode 11.4.1 Introduction of Master/Slave Mode AS01DNET-A can work as a DeviceNet master as well as slave with at most 4 AS01DNET modules connectable to the 11 right side of AS PLC. Running on the right of AS-series PLC, AS01DNET-A with AS-series PLC together constitutes the DeviceNet master or slave. When working in Master/Slave mode, AS01DNET-A is required to switch the function toggle (RTU- Master/Slave) to Master/Slave mode and the DeviceNet Builder of version 2.04 and above is used for the setup. For details about the setup, refer to Section 11.4.10. As a master, AS01DNET-A can provide the following function.
Supporting the Client function of Explicit message; Supporting IO polling connection with slaves; The network configuration software DeviceNet Builder provides graphic configuration interface. Sending explicit messages to read and write the data in slave through the explicit message instruction DNETRW. Automatically performing data exchange with the PLC module; users just need write a program for D register in the PLC without using FROM/TO instructions. Offering 190 bytes of output data area and 190 bytes of input data area for exchanging data with the master. As a slave, AS01DNET-A can provide the following function.
Explicit message Server and Group 2 only server connection mode; Polling connection; Offering 200 bytes of input data area and 200 bytes of output data area for exchanging data with master; Automatically exchanging data with the PLC. The user just need to write a program for D register in the PLC without using FROM/TO instruction. 11.4.1.1. Scan List, Input Table and Output Table 11-13 Item Description Figure Scan List Before AS01DNET-A module works, the scan list must be configured through the configuration software. The scan list stores slave information including node address, I/O type, I/O size and etc. for data exchange.
The scanner module manages the slaves in the scan list, makes a connection with slaves and exchange I/O data with them. For those slaves which have not been configured to the scan list, AS01DNET-A will not make a connection and I/O data exchange with them.