Delta Electronics — 11.4.8.1. Principle of Explicit Message Transmission

Chapter 11 DeviceNet Master Scanner Module AS01DNET-A 11 Program Explanation: 1. When M0 changes to ON, the value 16#5555 is written to D26105~D26108 in AS PLC. The data are transmitted to the slave cyclically via DeviceNet Bus. 2. The contents in D26005~D26008 are the data which the master receives from the slave via DeviceNet Bus. When M1 changes to ON, the data in D26005~D26008 are moved to D0, D1, D2 and D3. 11.4.8 Sending Explicit Message through Ladder Diagram AS01DNET-A supports the sending of explicit messages via DNETRW instruction. 11.4.8.1. Principle of Explicit Message Transmission 1.

AS PLC transmits the explicit request message to AS01DNET-A master according to the user program. 2. AS01DNET-A transmits the explicit request message to the slave according to the user program. 3. The slave sends back the response message to AS01DNET-A master after handling data. 4. AS PLC gets back the response message from AS01DNET-A master. Then the explicit message transmission of this time is finished. 11-29