AS Series Module Manual 13.3.1.9 Detection of Short-Circuits in I/O Cables This function detects short-circuits in I/O cables. The status code for communication ports will show 16#8CA4 if an error occurs. 13.3.1.10 Event Log The IO-Link event codes listed in section 13.5 are refreshed in the mapped devices for ports in the Normal Exchange Area section as below. _13 The device status for each port should be set to 3 bytes in length. See the following table of above device addresses corresponding to ports in order. Device status consists of Event qualifier and Event Code as follows. For event codes, see section 13.5. The data frame of Event Qualifier: Bit 0~ Bit 2:

INSTANCE 13-12 Description Address Port 1 D29022 H, D29022 L, D29023 H _ _ _ Port 2 D29023 L, D29024 H, D29024 L _ _ _ Port 3 D29025 H, D29025 L, D29026 H _ _ _ Port 4 D29026 L, D29027 H, D29027 L _ _ _ Event Qualifier Event Code Byte 0 Byte 1 Byte 2 MODE TYPE SOURCE INSTANCE Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Value Definition 0 Unknown 1-3 Reserved 4 Application 5-7 Reserved