Chapter 13 IO-Link Communication Module AS04SIL Bit 3: SOURCE Bit 4~ Bit 5: TYPE 13 Bit 6~ Bit 7: MODE 13.3.1.11 Notification of Input Data Invalidity Input Invalid Flag is used to determine whether the process input data in the upper device is invalid for the IO-Link communication or not. Whether the input data is invalid or not can be monitored by Port1 – 4(IO-Link Process Data) Input Invalid Flag of the Normal Exchange Area section. If the flag is 1, then the input data is invalid. If it is 0, the input data is valid. See the example in the following figure. D29028.0~ D29028.3 correspond to Port 1~Port 4 respectively as shown in the following table.
The mapped register for Port1 – 4(IO-Link Process Data) Input Invalid Flag is D29028 and for the input invalid flag, 13-13 Value Definition 0 Device (Remote) 1 Master (Local) Value Definition 0 Reserved 1 Notification 2 Warning 3 Error Value Definition 0 Reserved 1 Event single shot 2 Event disappears 3 Event appears Communication Port Address Port 1 D29028.0 Port 2 D29028.1 Port 3 D29028.2 Port 4 D29028.3